Features |
- Sine/cosine encoder signal monitoring for SIL applications
- Suitable for differential encoder signals of 1 Vpp (250 mV amplitude per line)
- Suitable for single-ended signals (500 mV amplitude per line)
- Monitor for input frequencies from 0 to 500 kHz
- Verification of DC common mode range per signal line
- Monitoring of Lissajous curve with min/max limits
- Cable fracture detection
- Source decoupling and overvoltage clamping per pin by external resistors
- Single-failure-proof dual channel concept
- Independent diagnostic outputs: signal OK message and signal error message
|