Features |
- Differential or single-ended inputs for up to 20 kHz
- Selectable adaptation to voltage or current signals
- Input multiplexers for flexible signal-to-channel assignment
- Programmable instrumentation amplifiers
- Signal conditioning for offset, amplitude and phase
- Automatic gain control with monitoring
- Short-circuit-proof analog output drivers (1 Vpp to 100 Ω)
- Immune against faulty output or supply connections
- Reverse polarity protection of the sub-system by power switch
- Adjustable thermal overload protection
- Monitoring functions with configurable error masking
- Alarm indication output
- Device setup from serial EEPROM (shared with iC-MSB)
- Footprint compatible to iC-MSB
- Single 5 V operation, from -40 °C to +115 °C
|