iC-MCB    SPI-to-BiSS Bridge with RS422 Transceiver

Applications
  • BiSS slave implementation
  • Multiple sensor devices
  • Encoder
  • Condition monitoring extension
  • Diagnosis extension
  • Torque sensor
  • Acceleration sensor
  • Inclinometer
  • Safety light curtain
Features
  • BiSS Interface slave
  • Full BiSS protocol support
  • Two data channel configurable
  • Three slave ID occupiable
  • Single cycle data buffer of 64 byte organized in multiple banks for simultaneous access
  • Built-in control communication
  • RS422 line driver/receiver for BiSS/SSI point-to-point network
  • BiSS bus structure capable
  • SPI slave interface for sensor data provided by microcontroller
  • Fast Sensor interface for direct sensor data provided by an SPI slave device
  • BiSS safety related features: two data channel: CPW and SPW (6/16 bit CRC + CRC start value)
  • BiSS timeout: adaptive, 2 μs, 20 μs
  • SSI protocol support
  • Operation from 3.0 V to 5.5 V
  • Operating temperature range of -40°C to +125°C
  • Space-saving 16-pin QFN package
Packages
    QFN16
SPI-TO-BiSS SLAVE BRIDGE WITH RS422 TRANSCEIVER
 