| Features |
- IO-Link compliant slave transceiver
- Dual channel switches, configurable for high-side, low-side and push-pull operation with tristate function
- Configuration via pins or SPI interface
- Switches are current limited
- Switches, iC supply and feedback channel are protected against reverse polarity
- Output current of up to 150 mA per channel
- Parallel connection of both channels possible
- The channels can be inverted for antivalent output
- Sensor communication request function (IO-Link wake-up)
- Wide supply voltage range of 9 to 30 V
- Sensor parametrisation via a feedback channel (up to 30 V)
- Switching converters and linear regulators for 3.3/5 V voltage generation
- Error detection with hysteresis with excess temperature, overload and undervoltage
- Driver shut-down on all errors
- Error signalling at two open-collector outputs
|